Rebuilding Physical Device
Rebuild means incorporation of a new Physical Device to a Logical Drive after a Physical Device is replaced with the new
one due to occurrence of an event such as a failure. In general, the Rebuild is automatically started by a function of the
RAID Controller called standby rebuild or hot-swap rebuild. Accordingly, manual Rebuild is not required so often. If
required, use the Universal RAID Utility.
Rebuild can be executed if [Status] of a Physical Device is set to [Failed] and [Status] of the
Logical Drive using the Physical Device is set to [Degraded].
Executing Rebuild
Rebuild is executed for a Physical Device. The procedure of executing Rebuild is described below.
Manual Rebuild is available only in the Advanced Mode.
RAID Viewer
Step 1 Start the RAID Viewer. Click the Physical Device used for the
Rebuild on the Tree View. Then click [Start Rebuild] on the [Control] menu.
Step 2 After the Rebuild is started, the progress
of the Rebuild appears on the Operation View.
At the completion of the Rebuild, [Status] on the
Operation View is changed to [Completed].