Checking Result of Executing Rebuild
You can find the result of executing Rebuild by checking the Tree View, the property of the Physical Device and
the RAID Log of the Universal RAID Utility.
If Rebuild succeeds, the icon of the Physical Device subject to the Rebuild changes to [Online] on the Tree View.
In addition, the [Status] in the Property tab of the Physical Device is set to [Online].
When detects something problem, Universal RAID Utility records the log in the RAID Log.
Setting Rebuild Priority
You can set the priority at which Rebuild is executed in the server. The procedure of setting the Rebuild Priority
is described below.
Setting Rebuild Priority are available only in the Advanced Mode.
RAID Viewer
Step 1 Start the RAID Viewer. Click the RAID Controller on the Tree View. Then click [Properties] on the [File] menu.
101
Step 2
Click the [Options] tab in the [RAID
Controller Properties] dialog box. Change the value of
[Rebuild Priority] to [High], [Middle], or [Low]. Click
[OK] or [Apply].
raidcmd
Step 1 Execute "optctrl" command with -rp option
and the defined parameters.
-c : Number of the RAID Controller for which Rebuild
Priority is set
-rp : Select high, middle, or low to change the Rebuild
Priority.
Ex. Set the Rebuild Priority of the RAID Controller
(RAID Controller number: 1) to Middle.
raidcmd optctrl -c=1 -rp=middle
Step 2 The property of the RAID Controller
changes to the following value when the setting has
been changed successfully.
[Rebuild Priority]: Priority after change
Check the execution result by using "property" command.
-tg : Specify rc to browse the property of Logical Drive
c : The number of the RAID Controller -
> raidcmd optctrl -c=1 -rp=middle
> ra
idcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Corporation
Model : MegaRAID SAS PCI Express(TM)
ROMB
Firmware Version : 1.12.02-0342
Cache Size : 128MB
Battery Status : Normal
Rebuild Priority : Middle
Consistency Check Priority : Low
Patrol Read : Enable
Patrol Read Priority : Low
Buzzer Setting : Enable
>
1
2
Ex. Browse the property of the RAID Controller (RAID Controller Number: 1)
raidcmd property -tg=rc -c=1