NEC Express5800/R110f-1E Manuel d'utilisateur Page 51

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 135
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 50
51
Item
RAID Viewer
Item
raidcmd
Description
Premium Feature Premium Feature Indicates the Premium Feature of RAID Controller.
Displayed only when Premium Feature is enable.
The possible status is as follow:
Cache Cade
- Battery Status Indicates the status of the Battery installed in the RAID Controller.
Three possible statuses are as follows:
Normal: Indicates that the Battery can be used normally.
Warning: Indicates that the Battery cannot be used normally due to some
reason.
Not Present: No battery with the RAID Controller.
- Flash Backup Unit Indicates the status of the Flash Backup Unit installed in the RAID Controller.
Three possible statuses are as follows:
Normal: Indicates that the Flash Backup Unit can be used normally.
Warning: Indicates that the Flash Backup Unit cannot be used normally due to
some reason.
Not Present: No Flash Backup Unit with the RAID Controller.
Initialize Priority Initialize Priority Indicates the priority level of Initialize executed in the server system.
Three possible Initialize Priorities are as follows:
High: Executes Initialize at high priority.
Middle: Executes Initialize at balanced priority.
Low: Executes Initialize at low priority.
Rebuild Priority Rebuild Priority Indicates the priority level of Rebuild executed in the server system.
Three possible Rebuild Priorities are as follows:
High: Executes Rebuild at high priority.
Middle: Executes Rebuild at balanced priority.
Low: Executes Rebuild at low priority.
Consistency Check
Priority
Consistency Check
Priority
Indicates the priority level of Consistency Check executed in the server system.
Three possible Consistency Check Priorities are as follows:
High: Executes Consistency Check at high priority.
Middle: Executes Consistency Check at balanced priority.
Low: Executes Consistency Check at low priority.
Patrol Read Patrol Read Indicates whether Patrol Read is executed or not.
Enable: Executes Patrol Read.
Disable: Does not execute Patrol Read.
Patrol Read Priority Patrol Read Priority Indicates the priority level of Patrol Read executed in the server system.
Three possible Patrol Read Priorities are as follows:
High: Executes Patrol Read at high priority.
Middle: Executes Patrol Read at balanced priority.
Low: Executes Patrol Read at low priority.
Buzzer Setting Buzzer Setting Indicates whether the Buzzer of the RAID Controller is used if a failure occurs in
the RAID System.
Enable: Enables the Buzzer.
Disable: Disables the Buzzer.
HDD Power Saving
(Hot Spare)
HDD Power Saving
(Hot Spare)
Indicates whether the HDD Power Saving (Hot Spare) is enable or not.
Enable; Spin down the Hot Spare that is not in use.
Disable: Does not spin down the Hot Spare that is not in use.
Device Standby Time Device Standby Time Indicates the time of transitioning to Power Saving of the Physical Device which
is not in use.
30 minutes
1 hour
2 hours
4 hours
8 hours
X hour/hours Y minute/minutes : Indicates this option if current Device Standby
Time is other value than listed above.
Vue de la page 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 134 135

Commentaires sur ces manuels

Pas de commentaire