NEC Express5800/R110f-1E Manuel d'utilisateur Page 118

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 135
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 117
Operation when redundancy of Logical Drive degraded or lost due to failure of Physical Device
If one or more Physical Devices used by a Logical Drive are failed (with their [Status] being [Failed]) to degraded (one Physical Device of RAID Level 6 is failed) or lost (one
Physical Device of RAID Level 1 or 5 is failed, two Physical Devices of RAID Level 6 is failed) the redundancy of the Logical Drive, the Logical Drive is degraded (with its [Status]
being [Degraded]).
Figure 25 Display of RAID Viewer / raidcmd (Lost the redundancy of Logical Drive)
> raidcmd property -tg=pd -c=1 -p= e252s3
RAID Controller #1 Physical Device e252s3
Enclosure : 252
Enclosure Position : Internal
Slot : 3
ID : 20
Device Type : HDD
Interface : SAS
Ve Andor/Model : SEAG TE ST936701SS
Firmware Version : 0003
Serial Number : 3LC05RDP
Capacity : 33GB
Status : Online
S.M.A.R.T. : Normal
Power Status : On
>
> raidcmd property -tg=pd -c=1 -p= e252s2
RAID Controller #1 Physical Device e252s2
Enclosure : 252
Enclosure Position : Internal
Slot : 2
ID : 19
Device Type : HDD
Interface : SAS
Vendor/Model : SEAGATE ST936701SS
Firmware Version : 0003
Serial Number : 3LC047LG
Capacity : 33GB
Status : Online
S.M.A.R.T. : Normal
Power Status : On
>
e252s5
[Hot Spare]
e252s4
[Failed]
#1 [De
g
raded]
RAID Level: 5
e252s2
[Online]
e252s3
[Online]
> raidcmd property -tg=pd -c=1 -p= e252s4
RAID Controller #1 Physical Device e252s4
Enclosure : 252
Enclosure Position : Internal
Slot : 4
ID : 21
Device Type : HDD
Interface : SAS
Vendor/Model : SEAGATE ST936701SS
Firmware Version : 0003
Serial Number : 3LC05ZZG
Capacity : 33GB
Status : Failed
S.M.A.R.T. : Normal
Power Status : On
>
> raidcmd property -tg=ld -c=1 -l=1
RAID Controller #1 Logical Drive #1
ID : 0
Disk Array Information : 1 (order 1/1)
RAID Level : RAID 5
Capacity : 20GB
Stripe Size : 64KB
Cache Mode (Setting) : Write Back
Cache Mode (Current) : Write Back
Type : Logical Drive
Status : Degraded
>
Structure and Status of RAID System Property of RAID Viewe
r
Property of raidcmd
Logical Drive
[Degraded]
Tree View of RAID Viewe
r
Become [Fatal] by
existence of
[Failed] node.
Failed Physical
Device
[Failed]
118