68 | NEC DISPLAY WALL CALIBRATOR - USER’S GUIDE
The Summary window is accessed from the View menu.
This window shows the current layout conguration and connections, as well as detailed information about the
calibration results.
Connection Summary:
Port - Shows the Communications Port to the display, either the RS232 COM Port, or LAN IP Address.
Monitor ID - Shows the Monitor ID used to identify the display monitor.
Model - Shows the model of the display monitor.
Serial Number - Shows the serial number of the display monitor.
Firmware Version - Shows the version of internal rmware of the display monitor.
Status - Shows the current status of the display monitor in the measurement and calibration process.
Calibration Summary:
Uncalibrated Intensity – Shows the measured native Intensity (luminance) of the display when un-calibrated.
Uncalibrated White Point – Shows the native white point of the display when un-calibrated.
Uncalibrated Contrast Ratio – Shows the native contrast ratio of the display when un-calibrated.
Maximum Calibrated Intensity – Shows the calculated maximum Intensity that can be achieved by the display
using the current Target White Point setting. If the current Target Intensity method is set to Specic Level and
the calculated value is more than 5% lower than the Target, then a yellow warning icon is shown to warn that
the displays may not match in Intensity after calibration using the current Specic Level value, and a lower
value should be chosen.
Date Measured – Shows the date and time that the un-calibrated measurements were taken.
Operating Hours when Measured – Shows the number of hours the display has been in operation at the time
the un-calibrated measurements were taken.
Actual Calibrated Intensity – Shows the Intensity (luminance) of the display after it has been calibrated. If the
current Target is set to Maximum Possible Matching or Specic Level and the value is not within 10% of the
Target Intensity value, then a yellow alert icon is shown to warn that the display could not achieve the desired