52 | NEC DISPLAY WALL CALIBRATOR - USER’S GUIDE
This panel allows measurements of colors displayed on the screen
to be taken with the calibration sensor and the numerical results
are displayed.
To take color measurements using the Colorimeter, display a white
image on the screen to be measured and place the calibration
sensor on the screen. Then click the Measure button to take a
single color measurement and display the results.
The measurement results are shown in CIE xyY and Color
Temperature.
The Color Temperature eld shows the corresponding correlated
black body radiator temperature of the measurement in Kelvin. The
Δuv (Delta-uv) value indicates how far the measurement is from the blackbody radiator locus. The Kelvin value is
only meaningful for colors that are near the black body radiator locus, such as most shades of white.
This feature can be used together with the Test Patterns tool to verify the calibration accuracy of a display. In this
case the Calibrated White function in the Test Pattern panel can be used to show a calibrated white screen, then
the sensor can be used to measure the screen.
It can also be used to measure the native white point of a display by using the 100% White function in the Test
Pattern panel to show a native white screen, which can then be measured using the sensor.