Troubleshooting 8-25
On-screen message Description Action
Proc1 T-Trip
The power was forcibly turned off
due to a CPU1 temperature
abnormality.
Proc2 T-Trip
The power was forcibly turned off
due to a CPU2 temperature
abnormality.
ChipSet T-Trip
The power was forcibly turned off
due to a chip set temperature
abnormality.
CPU1_DIMM U-Err
An unrecoverable error occurred
for a CPU1 DIMM.
CPU2_DIMM U-Err
An unrecoverable error occurred
for a CPU2 DIMM.
Processor1 IERR
An internal CPU1 error (IERR)
occurred.
Processor2 IERR
An internal CPU2 error (IERR)
occurred.
SMI timeout
A timeout occurred while servicing
system management interrupts.
WDT timeout
A watchdog timer timeout
occurred.
HDD 1 Fault
HDD 2 Fault
HDD 3 Fault
HDD 4 Fault
HDD 5 Fault
HDD 6 Fault
HDD 7 Fault
HDD 8 Fault
HDD 9 Fault*
HDD 10 Fault*
HDD 11 Fault*
HDD 12 Fault*
Operation was performed while
the hard disk drive had a failed
status (supported only when the
onboard RAID controller
(N8103-129/130) is used).
HDD 7 Fault and HDD 8 Fault only
apply to 2.5-inch hard disk drive
models.
* These apply to 2.5-inch HDD
models to which N8154-35 has
been added.
Contact your service
representative.
Sys Fan 1R Alarm
Sys Fan 2R Alarm
Sys Fan 3R Alarm
Sys Fan 4R Alarm
Sys Fan 1F Alarm
Sys Fan 2F Alarm
Sys Fan 3F Alarm
Sys Fan 4F Alarm
A fan alarm was detected.
It is possible that a fan has failed
or is clogged up. Contact your
service representative and
request repairs.