8-14 Troubleshooting
Displayed Error Message Description Recommended Action
AE83
CPU1_DIMM3 with error
enabled.
CPU1_DIMM3 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
AE87
CPU2_DIMM1 with error
enabled.
CPU2_DIMM1 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
AE88
CPU2_DIMM2 with error
enabled.
CPU2_DIMM2 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
AE89
CPU2_DIMM3 with error
enabled.
CPU2_DIMM3 was disabled,
but, because all memory is
currently disabled, this DIMM
was forcibly enabled.
Contact your service
representative.
B000
DXE_LEGACY_OPROM_
NO_SPACE
There is no space for expanding
option ROM.
B001
Expansion ROM not
initialized - PCI Slot 1B
Option ROM expansion in PCI
slot 1B failed.
B002
Expansion ROM not
initialized - PCI Slot 2B
Option ROM expansion in PCI
slot 2B failed.
B003
Expansion ROM not
initialized - PCI Slot 3B
Option ROM expansion in PCI
slot 3B failed.
B004
Expansion ROM not
initialized - PCI Slot 1C
Option ROM expansion in PCI
slot 1C failed.
B005
Expansion ROM not
initialized - PCI Slot 2C
Option ROM expansion in PCI
slot 2C failed.
B006
Expansion ROM not
initialized - PCI Slot 3C
Option ROM expansion in PCI
slot 3C failed.
If the board is not used
as a boot device,
disable the Option
ROM Scan for that
board.
B030 PCI System Error on
Bus/Device/Function
PCI SERR was detected.
B040
PCI Parity Error on
Bus/Device/Function
PCI PERR was detected.
C010
The error occurred during
temperature sensor
reading
An error was detected while
reading the temperature sensor.
Contact your service
representative.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that a fan
has failed or is clogged
up. Contact your
service representative
and request repairs.
C020
The error occurred during
voltage sensor reading.
An error was detected while
reading the voltage sensor.
Contact your service
representative.
Vue de la page 286