14
optctrl
[Overview]
Allows you to set optional parameters of a RAID Controller.
[Format]
raidcmd optctrl -c=<controller> {-ip={high | middle | low} | -rp={high | middle | low} | -ccp={high | middle | low}
| -pr={enable | disable} | -prp={high | middle | low} | -be={enable | disable} | -psd={none | hotspare} |
-dst={0.5 | 1 | 2 | 4 | 8} }
Command Parameter Description
-c=<controller> Specify the RAID Controller to be processed.
<controller> : RAID Controller Number
-ip={high | middle | low} Specify the Initialize Priority.
high: High priority
middle: Middle priority
low: Low priority
-rp={high | middle | low} Specify the Rebuild Priority.
high: High priority
middle: Middle priority
low: Low priority
-ccp={high | middle | low} Specify the Consistency Check Priority.
high: High priority
middle: Middle priority
low: Low priority
-pr={enable | disable} Specify whether Patrol Read is executed or not.
enable: Executed
disable: Not executed
-prp={high | middle | low} Specify the Patrol Read Priority.
high: High priority
middle: Middle priority
low: Low priority
-be={enable | disable} Specify whether the Buzzer is enabled or disabled.
enable: Enabled
disable: Disabled
-psd={none | hotspare} Specify the Power Saving Device.
none : Power Saving of all Physical Device is "disable".
hotspare : Power Saving of Hot Spare is "enable".
-dst={0.5 | 1 | 2 | 4 | 8} Specify the Device Standby Time.
0.5 : 30minutes
1 : 1hour
2 : 2hours
4 : 4hours
8 : 8hours
[Description]
Allows you to set optional parameters of the specified RAID Controller (including Initialize Priority, Rebuild Priority,
Consistency Check Priority, Patrol Read execution and Priority, Buzzer enable/disable, HDD Power Saving, and
Device Standby Time).
Only a single parameter can be set at a time. Concurrent set of more than one parameter is disabled.
[Condition]
This command can be executed only in the Advanced Mode.