NEC Express5800 Series
MegaRAID Storage Manager
User's Guide
- Windows Edition -
7th Edition
12-2006
808-882425-676-G
Vue de la page 0
1 2 3 4 5 6 ... 76 77

Résumé du contenu

Page 1 - - Windows Edition

NEC Express5800 Series MegaRAID Storage Manager™ User's Guide - Windows Edition - 7th Edition 12-2006 808-882425-676-G

Page 2 - Preface

6 Installing and Uninstalling MSM 4. The installation is started. When MSM has been installed, the [Setup finished] dialog box appears. Select [Yes

Page 3 - Contents

Installing and Uninstalling MSM 7 2.2.2 Uninstalling MSM from Server Uninstall MSM in the following procedure: IMPORTANT: Do not uninstall MSM thro

Page 4

8 Installing and Uninstalling MSM 2.3 MSM Operation Environment (Management PC) The following shows the hardware and software operation environment

Page 5 - 1. Overview

Installing and Uninstalling MSM 9 2.4.1 Installing MSM to Management PC Install MSM in the following procedure: 1. Insert the NEC EXPRESSBUILDER CD

Page 6 - 2 Overview

10 Installing and Uninstalling MSM 6. The screen shown below appears. Click [Next]. To change the installation folder, click [Change] and specify a

Page 7

Installing and Uninstalling MSM 11 2.4.2 Uninstalling MSM from Management PC Uninstall MSM in the following procedure: IMPORTANT: Do not uninstall

Page 8

12 Installing and Uninstalling MSM 5. The screen shown below appears. Click [Remove]. 6. The screen shown below appears. Click [Finish]. Now the

Page 9

Operation 13 3. Operation This chapter describes how to start MSM and how to operate MSM. The supported features of MSM are depended on MegaRAID Sto

Page 10

14 Operation 3.1.1 Controlling MegaRAID Storage System with Local/Remote Computer To control MSM with local and/or remote computers, start MSM in the

Page 11

Operation 15 A circle icon appears on each host in the server selection screen. The host status is shown by one of the following colors: Green: Norma

Page 12

Preface The User's Guide explains the utility MegaRAID Storage Manager™ to be used for “LSI Logic Embedded MegaRAID(tm)”, “N8103-91 Disk Array C

Page 13

16 Operation 3.2 MSM Operation Screen An example of the MSM screen is shown below (after logged in, the screen shown below appears). MSM has four s

Page 14

Operation 17 3.2.1 Menu Bar Selectable objects on the menu bar can also be selected/executed by right-clicking them. The menu bar appears as follows:

Page 15

18 Operation  [Log] menu On the [Log] menu, you can select the following items: [Save Log]: Save the logs appearing in the Event Viewer to the spe

Page 16

Operation 19 3.2.2 Physical/Logical View On the Physical/Logical View, the physical and logical drives connected to the disk array controller are dis

Page 17 - 3. Operation

20 Operation [Scan For Foreign Config]: Read configuration info from HDD and try to rebuild array by using that info. This feature is not supported.

Page 18 - Computer

Operation 21 When physical drive is in offline status: [Make Drive Online]: Makes the physical drive online. The feature is dedicated for maintenan

Page 19 - Operation 15

22 Operation When physical drive is not used yet: [Locate Physical Drive]: Start to blink LED of Physical disk. [Stop Locating Physical Drive]: Sto

Page 20 - 3.2 MSM Operation Screen

Operation 23  Menu appearing when right-clicking Virtual Disk [Context Menu] : The menu appearing when right-clicking Virtual Disk varies depending

Page 21 - 3.2.1 Menu Bar

24 Operation When logical drive is degraded: [Check Consistency] disappears to be unavailable while it is displayed if the logical drive operates nor

Page 22 - 18 Operation

Operation 25 3.2.3 Properties /Operations/Graphical View The Properties/Operations/Graphical view indicates the information on controllers and drive

Page 24 - 20 Operation

26 Operation [Start Patrol Read / Stop Patrol Read]: Start or stop the Patrol Read. The screen display varies depending on how the Patrol Read is exe

Page 25 - Operation 21

Operation 27 When physical drive is selected (under rebuild processing): [Abort Rebuild]: Abort the rebuild processing. [Locate Physical Drive]: Sta

Page 26 - 22 Operation

28 Operation When physical drive is selected (being hot-spare disk): [Remove Hotspare]: Release the setting as a hot-spare disk. [Locate Physical D

Page 27 - Operation 23

Operation 29 [Prepare For Removal]/ [Undo Prepare For Removal]: Do not use the feature. It's the function which stops and restarts a revolution

Page 28 - 24 Operation

30 Operation When logical drive is selected (in execution of consistency check): [Delete Virtual Disk]: Select this feature to delete the logical dr

Page 29 - Operation 25

Operation 31  Graphical View Indicate the capacity of the selected drive graphically. The following shows the sample displays of physical and logi

Page 30 - 26 Operation

32 Operation 3.2.4 Event Viewer The Event Viewer indicates the log information acquired in the period from the time at which the server is started.

Page 31 - Operation 27

Operation 33 3.3 Creating and Deleting Logical Drive (Array) The creation method of a logical drive and the deletion method are explained here. If

Page 32 - 28 Operation

34 Operation 3.3.1 Creating Logical Drive You can create a logical drive on the Configuration Wizard appearing by right-clicking the controller in t

Page 33 - Operation 29

Operation 35 3.3.1.1 Auto Configuration The auto configuration mode allows the draft of the logical drive configuration to be created automatically d

Page 34 - 30 Operation

(This page is intentionally left blank.)

Page 35 - Operation 31

36 Operation Redundancy Type [No Redundancy]: Do not provide redundant array configuration. [With Redundancy]: Provide redundant array configuration

Page 36 - 3.2.4 Event Viewer

Operation 37 4. Set parameters in Virtual Disk Properties appropriately and click [Accept]. Then click [Next]. [RAID Level]: Select the RAID level

Page 37 - Operation 33

38 Operation [IO Policy]: Select either Direct IO or Cached IO. The default setting is Direct IO. [Access Policy]: Select Read Write, Read Only, or

Page 38 - 34 Operation

Operation 39 3.3.1.3 Guided Configuration The guided configuration mode allows a logical drive to be created by specifying setting items sequentiall

Page 39 - 3.3.1.1 Auto Configuration

40 Operation [Don’t use Existing Arrays]: Do not use existing arrays. [Use Existing and New Arrays]: Use both existing and new arrays. 3. Specify t

Page 40 - 3.3.1.2 Manual Configuration

Operation 41 [Init State]: Select the logical drive initialization procedure out of No Initialization, Fast Initialization and Full Initialization.

Page 41 - Operation 37

42 Operation 3.4 Check Consistency Feature The check consistency feature checks consistency and automatically corrects data if some inconsistency is

Page 42 - 38 Operation

Operation 43 2. Check one or more logical drives to be subject to the check consistency in [Select Virtual Disks] and click [Start]. [Select All]:

Page 43 - 3.3.1.3 Guided Configuration

44 Operation Starting execution on [Operations] tab 1. Select a logical drive on the Logical view and select the [Operations] tab. 2. Check [Check

Page 44 - 40 Operation

Operation 45 3.4.2 Canceling Check Consistency The check consistency can be cancelled in the following procedure. Check consistency canceling proce

Page 45 - Operation 41

Overview 1 1. Overview 1.1 MegaRAID Storage Manager™ MegaRAID Storage Manager™ (hereafter abbreviated for MSM) is an application that locally or rem

Page 46 - 42 Operation

46 Operation 3.5 Patrol Read Feature The Patrol Read feature operates in physical drives configuring all arrays including hot-spare disks to detect

Page 47 - Operation 43

Operation 47 To interrupt the Patrol Read being executed, click [Operations] → [Stop Patrol Read].

Page 48 - 44 Operation

48 Operation 3.5.2 Scheduling Patrol Read The Patrol Read can be scheduled in the following procedure. Patrol Read scheduling procedure 1. Select a

Page 49 - Operation 45

Operation 49 [Execution Frequency]: Specify the interval at which the Patrol Read is executed. You can set the interval in hours, minutes, or seconds

Page 50 - 3.5 Patrol Read Feature

50 Operation 3.6 Rebuild Feature The rebuild feature can recovers a degraded array. Before the feature can be used, the defected hard disk drive must

Page 51 - Operation 47

Operation 51 3.6.1 Hot-swap Rebuild The feature can be done in the following procedure: 1. Find the defected hard disk drive. The following figure s

Page 52 - 3.5.2 Scheduling Patrol Read

52 Operation 3.6.2 Hot-spare Rebuild 3.6.2.1 Hot-spare Disk Setting Procedure Global hot-spare setting procedure 1. Specify an unused hard disk driv

Page 53 - Operation 49

Operation 53 3.7 Reconstruction Feature The reconstruction feature allows you to increase in the capacity of an existing array and/or change its RAID

Page 54 - 3.6 Rebuild Feature

54 Operation The reconstruction is divided into three types; Add Drive, Remove Drive and Change RAID Level. [Add Drive]: Add a physical drive to the

Page 55 - 3.6.1 Hot-swap Rebuild

Operation 55 2. Select the physical drive to be added from the upper list and click the button to move the physical drive to the lower list. Then cl

Page 56 - 3.6.2 Hot-spare Rebuild

2 Overview  Auto array rebuild feature in array degrading MSM supports the hot-spare rebuild executed at the insertion/removal of a disk and the ho

Page 57 - 3.7 Reconstruction Feature

56 Operation 3.7.1.2 Remove Drive This feature removes the physical drive from the logical drive and converts the RAID level to RAID 0. The procedure

Page 58 - 3.7.1.1 Add Drive

Operation 57 3.7.1.3 Change RAID Level This feature converts the RAID level to RAID 0. The procedure is described below. 1. Click [Change RAID Leve

Page 59 - Operation 55

58 Operation 3.8 Help Selecting [Help] → [Help] on the menu bar allows the help normally attached to MSM to be displayed. NOTE: The help normally att

Page 60 - 3.7.1.2 Remove Drive

Miscellaneous Information 59 4. Miscellaneous Information 4.1 Supported function of MegaRAID Systems Supported function of MSM depends on the MegaRA

Page 61 - 3.7.1.3 Change RAID Level

60 Miscellaneous Information 4.2 How to confirm the type of Hot Spare Disks You could confirm the type of Created Hot Spare Disks by MSM. There are

Page 62 - 3.8 Help

CAUTIONS AND RESTRICTIONS 61 5. CAUTIONS AND RESTRICTIONS 5.1 Common Cautions and Restrictions for MegaRAID Storage Systems(SAS/SATA) Installing /

Page 63 - 4. Miscellaneous Information

62 CAUTIONS AND RESTRICTIONS The MSM log may be reviewed to see accesses from other clients.  You can specify the local users only as the Administr

Page 64

CAUTIONS AND RESTRICTIONS 63 Patrol Read feature  If the server is restarted, the Patrol Read feature is aborted. If you restart the Patrol Read af

Page 65 - 5. CAUTIONS AND RESTRICTIONS

64 CAUTIONS AND RESTRICTIONS 5.2 Cautions and Restrictions for N8103-90 Disk array controller(External SAS HDD) and N8103-91 Disk array controller(

Page 66

CAUTIONS AND RESTRICTIONS 65 • To avoid selecting wrong drives, it is highly recommended to check them properly by executing ‘Locate Physical Drive’

Page 67

Installing and Uninstalling MSM 3 2. Installing and Uninstalling MSM 2.1 MSM Operation Environment (Server Specification) The following shows the h

Page 68

66 CAUTIONS AND RESTRICTIONS 5.3 Cautions and Restrictions for LSI Logic Embedded MegaRAID™ MSM Operation  MSM can not set "Virtual Disk Pro

Page 69

CAUTIONS AND RESTRICTIONS 67  Guided Configuration". Miscellaneous  MSM logs are shown as GMT. The system event logs are shown correctly b

Page 70 - MegaRAID™

68 CAUTIONS AND RESTRICTIONS Appendix A Report Monitoring Event messages associated with the MegaRAID Storage system can be displayed on the NEC ESM

Page 71

CAUTIONS AND RESTRICTIONS 69 Alert report messages and actions against the messages If MSM is installed, the following messages registered as "M

Page 72 - Report Monitoring

70 CAUTIONS AND RESTRICTIONS 57 Consistency Check corrected medium error: If the error occurs frequently, take the preventive replacement of physical

Page 73

CAUTIONS AND RESTRICTIONS 71 102 Rebuild failed due to target drive error: The target physical drive may be damaged. Take the replacement of the phys

Page 74

72 CAUTIONS AND RESTRICTIONS 166 Communication lost on enclosure: Check the connection of the enclosure. √ √ 168 Fan failed on enclosure: Check th

Page 75

CAUTIONS AND RESTRICTIONS 73 216 FAILED Test: The test detects an error. Take the replacement of the disk array controller into account. √ √ 221

Page 76

4 Installing and Uninstalling MSM 2.2 Installing and Uninstalling MSM in Server This section describes the installation and uninstallation of MSM i

Page 77

Installing and Uninstalling MSM 5 2.2.1 Installing MSM to Server Install MSM in the following procedure: 1. Insert the NEC EXPRESSBUILDER CD-ROM i