76
raidcmd
Use "optctrl" command.
Step 1 Execute "optctrl" command with -ccp
option and the following parameters.
-c : Number of the RAID Controller for which Consistency
Check Priority is set
-ccp : Value set after Consistency Check Priority is
set(Select a value out of high, middle, and low)
Step 2 Check the execution result by using
"
property" command.
> raidcmd optctrl -c=1 -ccp=middle
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Corporation
Model : MegaRAID SAS PCI Express(TM)
ROMB
Firmware Version : 1.12.02-0342
Cache Size : 128MB
Battery Status : Normal
Rebuild Priority : High
Consistency Check Priority : Middle
Patrol Read : Enable
Patrol Read Priority : Low
Buzzer Setting : Enable
>