Problem Solving 5-27
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message Description Action
0B93 BMC SDR Repository empty
0B94 IPMB signal lines do not
respond
0B95
BMC FRU device failure
0B96 BMC SDR Repository failure
0B97 BMC SEL device failure
BMC is faulty.
•
Replace the PCI module
board.
0B98 BMC SEL Overflow
SEL (System Event Log)
overflowed.
•
Clear the SEL.
0BB0
SMBIOS - SROM data read
error
0BB1
SMBIOS - SROM data
checksum bad
•
SROM is faulty.
•
Front panel board is faulty.
•
Replace the front panel board.
0BD0
1st SMBus device address not
acknowledged
0BD1
1st SMBus device Errror
detected
0BD2
1st SMBus timeout
0BD3
2nd SMBus device address not
acknowledged
0BD4
2nd SMBus device Errror
detected
0BD5
2nd SMBus timeout
0BD6
3rd SMBus device address not
acknowledged
0BD7
3rd SMBus device Errror
detected
0BD8
3rd SMBus timeout
0BE2
7th SMBus device address not
acknowledged
0BE3
7th SMBus device Errror
detected
0BE4
7th SMBus timeout
0BE5
8th SMBus device address not
acknowledged
0BE6 8th SMBus device Errror
detected
0BE7 8th SMBus timeout
Board is faulty.
•
Check cable connection.
•
Replace the board.
Commentaires sur ces manuels