ND-24219ISSUE 2STOCK # 151980Very Small Platform System ManualNEAX2000 IVS Family of ProductsAUGUST, 1998NEC America, Inc.®1
REGULATORY INFORMATION NDA-24219 Page viiiRevision 2.0Note: Limitations on features exist if the system is registered as a KF system. Refer to Featur
CHAPTER 3 NDA-24219 Page 86Revision 2.0NAP-200-007Sheet 37/55Termination of Cables on MDF• If a D.C. voltage is supplied with the tone from the exter
NDA-24219 CHAPTER 3Page 87Revision 2.0NAP-200-007Sheet 38/55Termination of Cables on MDF(11) External BGM SourceFigure 007-28 and Figure 007-29 show
CHAPTER 3 NDA-24219 Page 88Revision 2.0NAP-200-007Sheet 39/55Termination of Cables on MDF(b) When using Pin Jacks on PN-TNTA (see Figure 007-29)Figur
NDA-24219 CHAPTER 3Page 89Revision 2.0NAP-200-007Sheet 40/55Termination of Cables on MDF(12) Power Failure Transfer (PFT)The PN-AUCA card or the PZ-8
CHAPTER 3 NDA-24219 Page 90Revision 2.0NAP-200-007Sheet 41/55Termination of Cables on MDFFigure 007-31 MDF Cross Connection for PFT (PN-AUCA)1262273
NDA-24219 CHAPTER 3Page 91Revision 2.0NAP-200-007Sheet 42/55Termination of Cables on MDFFigure 007-31 MDF Cross Connection for PFT (PN-AUCA) (Contin
CHAPTER 3 NDA-24219 Page 92Revision 2.0NAP-200-007Sheet 43/55Termination of Cables on MDF(b) When using PZ-8PFTA card• Figure 007-32 shows an outline
NDA-24219 CHAPTER 3Page 93Revision 2.0NAP-200-007Sheet 44/55Termination of Cables on MDFSTEP 1:Mount the PFT bracket to the PIM as indicated in Figur
CHAPTER 3 NDA-24219 Page 94Revision 2.0NAP-200-007Sheet 45/55Termination of Cables on MDF• Install the PZ-8PFTA card to the PIM according to the foll
NDA-24219 CHAPTER 3Page 95Revision 2.0NAP-200-007Sheet 46/55Termination of Cables on MDFSTEP 3:Connect the 25-pair cables on the MDF referring Figure
NDA-24219 REGULATORY INFORMATIONPage ixRevision 2.0(b) This equipment returns answer supervision on all DID calls forwarded to the PSTN. Permissible
CHAPTER 3 NDA-24219 Page 96Revision 2.0NAP-200-007Sheet 47/55Termination of Cables on MDF• Figure 007-36 shows the MDF cross connection for the No. 0
NDA-24219 CHAPTER 3Page 97Revision 2.0NAP-200-007Sheet 48/55Termination of Cables on MDFFigure 007-36 MDF Cross Connection for PFT (PZ-8PFTA) (Conti
CHAPTER 3 NDA-24219 Page 98Revision 2.0NAP-200-007Sheet 49/55Termination of Cables on MDF(13) Alarm Display PanelFigure 007-37 shows the cross connec
NDA-24219 CHAPTER 3Page 99Revision 2.0NAP-200-007Sheet 50/55Termination of Cables on MDF(14) SN716 DESKCON(a) Installation of SN716 DESKCON (see Figu
CHAPTER 3 NDA-24219 Page 100Revision 2.0NAP-200-007Sheet 51/55Termination of Cables on MDFSTEP 2:Plug the line cord from the modular jack into the mo
NDA-24219 CHAPTER 3Page 101Revision 2.0NAP-200-007Sheet 52/55Termination of Cables on MDF(b) MDF Cross Connection with AC Adapter Power Option (see F
CHAPTER 3 NDA-24219 Page 102Revision 2.0NAP-200-007Sheet 53/55Termination of Cables on MDF(c) MDF Cross Connection via PN-PW00 Power Option (see Figu
NDA-24219 CHAPTER 3Page 103Revision 2.0NAP-200-007Sheet 54/55Termination of Cables on MDF(15) Single Line Device Interface - Recommended MethodThe NE
CHAPTER 3 NDA-24219 Page 104Revision 2.0NAP-200-007Sheet 55/55Termination of Cables on MDF(16) Message Center Interface Connection for VM00 to AP00 (
NDA-24219 CHAPTER 3Page 105Revision 2.0NAP-200-008Sheet 1/10Switch Setting of Circuit Card1. CIRCUIT CARDS SWITCH SETTINGTable 008-1 shows the contro
REGULATORY INFORMATION NDA-24219 Page xRevision 2.0Repairs to certified equipment should be made by an authorized Canadian maintenance facility desig
CHAPTER 3 NDA-24219 Page 106Revision 2.0NAP-200-008Sheet 2/10Switch Setting of Circuit Card2. PN-CP03 (MP)(1) Locations of Lamps, Switches, and Conne
NDA-24219 CHAPTER 3Page 107Revision 2.0NAP-200-008Sheet 3/10Switch Setting of Circuit Card(3) Switch Setting (see Table 008-4)Table 008-4 PN-CP03 (M
CHAPTER 3 NDA-24219 Page 108Revision 2.0NAP-200-008Sheet 4/10Switch Setting of Circuit CardThe figure in the SWITCH NAME column and the position in
NDA-24219 CHAPTER 3Page 109Revision 2.0NAP-200-008Sheet 5/10Switch Setting of Circuit CardCAUTION:When the operating power is being supplied to this
CHAPTER 3 NDA-24219 Page 110Revision 2.0NAP-200-008Sheet 6/10Switch Setting of Circuit CardFigure 008-2 PZ-PW86 (PWR) Card (Continued)(2) Lamp Indic
NDA-24219 CHAPTER 3Page 111Revision 2.0NAP-200-008Sheet 7/10Switch Setting of Circuit Card(3) Switch Settings (see Table 008-6)The figure in the SWIT
CHAPTER 3 NDA-24219 Page 112Revision 2.0NAP-200-008Sheet 8/10Switch Setting of Circuit CardCAUTION:When the operating power is being supplied to this
NDA-24219 CHAPTER 3Page 113Revision 2.0NAP-200-008Sheet 9/10Switch Setting of Circuit Card(2) Lamp Indications (see Table 008-7)(3) Switch Settings (
CHAPTER 3 NDA-24219 Page 114Revision 2.0NAP-200-008Sheet 10/10Switch Setting of Circuit Card5.PN-8COTM/8COTP(1) Locations of Lamps, Switches and Conn
NDA-24219 CHAPTER 3Page 115Revision 2.0NAP-200-009Sheet 1/3Mounting Circuit Cards1. MOUNTING PROCEDURE(1) For testing, turn on “SW1” switch on the PZ
NDA-24219 REGULATORY INFORMATIONPage xiRevision 2.0(10) Slots and openings in the cabinet and the back or bottom are provided for ventilation, to pr
CHAPTER 3 NDA-24219 Page 116Revision 2.0NAP-200-009Sheet 2/3Mounting Circuit Cards(3) Before mounting the circuit cards, confirm the following items.
NDA-24219 CHAPTER 3Page 117Revision 2.0NAP-200-009Sheet 3/3Mounting Circuit Cards(5) Install the Card Stopper according to the following procedure:(a
CHAPTER 3 NDA-24219 Page 118Revision 2.0NAP-200-010Sheet 1/7System Initialization and System Data Entry1. SYSTEM INITIALIZATION• There are two method
NDA-24219 CHAPTER 3Page 119Revision 2.0NAP-200-010Sheet 2/7System Initialization and System Data Entry2. SYSTEM DATA ENTRY• There are two methods for
CHAPTER 3 NDA-24219 Page 120Revision 2.0NAP-200-010Sheet 3/7System Initialization and System Data EntryTo reset CAT mode:While “COMMAND = -” is displ
NDA-24219 CHAPTER 3Page 121Revision 2.0NAP-200-010Sheet 4/7System Initialization and System Data Entry(1) Programming Procedure for Music On HoldFor
CHAPTER 3 NDA-24219 Page 122Revision 2.0NAP-200-010Sheet 5/7System Initialization and System Data EntryFor providing External Hold Tone Source throug
NDA-24219 CHAPTER 3Page 123Revision 2.0NAP-200-010Sheet 6/7System Initialization and System Data Entry(2) Programming Procedure for Pushbutton Callin
CHAPTER 3 NDA-24219 Page 124Revision 2.0NAP-200-010Sheet 7/7System Initialization and System Data EntryDESCRIPTION DATAAssign the type of signaling (
NDA-24219 CHAPTER 3Page 125Revision 2.0NAP-200-011Sheet 1/1Operation Test1. OPERATION TESTConfirm the entered system data and hardware, including cab
REGULATORY INFORMATION NDA-24219 Page xiiRevision 2.0This page is for your notes.
CHAPTER 3 NDA-24219 Page 126Revision 2.0NAP-200-012Sheet 1/1Cleaning and Visual Check1. CLEANINGClean the following places:• Inside of the main equip
NDA-24219 CHAPTER 3Page 127Revision 2.0NAP-200-013Sheet 1/1Mounting of Front Cover1. MOUNTING FRONT COVERMount the Front Cover onto PIM using the pro
CHAPTER 3 NDA-24219 Page 128Revision 2.0This page is for your notes.
NDA-24219 CHAPTER 4Page 129Revision 2.0CHAPTER 4 OFFICE DATA PROGRAMMING1.CUSTOMIZING DATA1.1 Data Programming ProcedureTable 4-1 shows the procedure
CHAPTER 4 NDA-24219 Page 130Revision 2.01.2.2 Station DataIn this table, the following data are required.• Station Number: Station numbers (up to fou
NDA-24219 CHAPTER 4Page 131Revision 2.0• NUMBER OF LINESpecify the number of trunks to be provided with each route (IC-Incoming, OG-Outgoing, BW-Both
CHAPTER 4 NDA-24219 Page 132Revision 2.01.2.6 Speed Calling-System DataThis data table requires the abbreviated code and the stored number to be sent
NDA-24219 CHAPTER 4Page 133Revision 2.0PN-AUCPN-2DLC• Station number must be assigned to 1st LEN (LEVEL 0) and/or 2nd LEN (LEVEL 1) of each LT slot.•
CHAPTER 4 NDA-24219 Page 134Revision 2.0PN-2DAT • Card number must be assigned to 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot.PN-8RST
NDA-24219 CHAPTER 4Page 135Revision 2.0PN-CFT • Card number must be assigned to 1st LEN (LEVEL 0) of each LT slot.PN-2DPC • To assign data station nu
NDA-24219 CHAPTER 1Page 1Revision 2.0CHAPTER 1 INTRODUCTION1. PURPOSEThis manual explains the installation procedure for the NEAX1000 IVS (PBX) Syste
CHAPTER 4 NDA-24219 Page 136Revision 2.0PN-2AMP • Card number must be assigned to the 1st LEN (LEVEL 0) and/or 3rd LEN (LEVEL 2) of each LT slot.PN-2
NDA-24219 CHAPTER 4Page 137Revision 2.01.3 Customer Specification SheetsThis section provides the various sheets for designing the customer specifica
CHAPTER 4 NDA-24219 Page 138Revision 2.01.3.2 Station DataTable 4-4 Station Data TableNote: If space is insufficient, use copies.Department or Secti
NDA-24219 CHAPTER 4Page 139Revision 2.01.3.3 Trunk DataTable 4-5 Trunk Data TableNote: If space is insufficient, use copies.PROGRAMMING: CM10, 30,
CHAPTER 4 NDA-24219 Page 140Revision 2.01.3.4 Station Hunting Group DataTable 4-6 Station Hunting Group Data TableNote: If space is insufficient, us
NDA-24219 CHAPTER 4Page 141Revision 2.01.3.5 Call Pickup Group DataTable 4-7 Call Pickup Group Data TableNote: If space is insufficient, use copies.
CHAPTER 4 NDA-24219 Page 142Revision 2.01.3.6 Speed Calling-System DataTable 4-8 Speed Calling-System Data TableNote: If space is insufficient, use
NDA-24219 CHAPTER 4Page 143Revision 2.01.4 System Configuration1.4.1 Port Assignment TableTable 4-9 Port Assignment Table LT00 LT01 LT02 LT03 LT04 L
CHAPTER 4 NDA-24219 Page 144Revision 2.01.4.2 Bay Face Layout for ModuleFigure 4-1 Module ConfigurationTable 4-10 Quantity Table for ModuleFUNCTIO
NDA-24219 CHAPTER 4Page 145Revision 2.01.4.3 Quantity Table for Circuit CardsTable 4-11 Quantity Table for Line/Trunk Circuit CardsFUNCTIONAL NAME(C
CHAPTER 1 NDA-24219 Page 2Revision 2.03. HOW TO FOLLOW THIS MANUALThe Installation Procedure is shown by means of flowcharts with an NAP (NEC Action P
CHAPTER 4 NDA-24219 Page 146Revision 2.0Table 4-13 Quantity Table for Application Circuit CardsFUNCTIONAL NAME(CARD NAME)QUANTITYFUNCTIONAL NAME(CAR
NDA-24219 CHAPTER 2Page 3Revision 2.0CHAPTER 2 GENERAL INFORMATION1. TRUNKING DIAGRAMFigure 2-1 shows a typical trunking diagram for the PBX.Figure 2
CHAPTER 2 NDA-24219 Page 4Revision 2.0Note: Refer to NAP-200-008 and the Circuit Card Manual for details of circuit cards.Table 2-1 Symbols in Trunk
NDA-24219 CHAPTER 2Page 5Revision 2.02. SYSTEM CONFIGURATIONS2.1 PIM ConfigurationThe PBX system can accommodate a maximum of 48 ports per PIM. A max
LIABILITY DISCLAIMERNEC America, Inc. reserves the right to change the specifications,functions, or features, at any time, without notice.NEC America,
CHAPTER 2 NDA-24219 Page 6Revision 2.02.2 Installation MethodsFigure 2-3 Wall-Mounting InstallationPIM
NDA-24219 CHAPTER 2Page 7Revision 2.0Figure 2-4 19-Inch Rack-Mounting InstallationPIM19”BRACKET (H)
CHAPTER 2 NDA-24219 Page 8Revision 2.0Figure 2-5 Desktop InstallationPIM
NDA-24219 CHAPTER 2Page 9Revision 2.03. FUNCTIONAL OUTLINE OF EQUIPMENTThis section explains the functional outline of the equipment (modules, instal
CHAPTER 2 NDA-24219 Page 10Revision 2.03.3 Functional Outline of Circuit Cards3.3.1 Control Circuit CardTable 2-4 shows the functional outline of eac
NDA-24219 CHAPTER 2Page 11Revision 2.03.3.2 Application Circuit CardsTable 2-5 shows the functional outline of each application circuit card.Table 2-
CHAPTER 2 NDA-24219 Page 12Revision 2.03.3.3 Line/Trunk Circuit CardsTable 2-6 shows the functional outline of each line/trunk circuit card.SPN-DAIA
NDA-24219 CHAPTER 2Page 13Revision 2.0PN-4DITB DIT 4-line Direct In-Dialing Trunk CardThis card is equipped with the function for loop detection, sen
CHAPTER 2 NDA-24219 Page 14Revision 2.0PN-8LCS LC 8-line Analog Line Circuit Card for single-line telephonesLoop resistance: Max. 600 ΩThis card is e
NDA-24219 CHAPTER 2Page 15Revision 2.0DTP-16-1 PN-8DLCJ / 8DLCP(STANDARD)656ft. (200m) Note 1PN-4DLCD / 4DLCQ(STANDARD)656ft. (200m)[3937ft. (1200m)]
NDA-24219ISSUE 2AUGUST, 1998NEAX1000 IVSVery Small Platform System ManualNEAX2000 IVS Family of ProductsTABLE OF CONTENTSPageLIST OF FIGURES. . . . .
CHAPTER 2 NDA-24219 Page 16Revision 2.0* The value in the [ ] shows the cable length when using the long line function.Note 1: When using PN-8DLCJ or
NDA-24219 CHAPTER 2Page 17Revision 2.04. CIRCUIT CARD INSTALLATION CONDITIONS4.1 Circuit Card Mounting SlotsFigure 2-6 shows circuit card mounting sl
CHAPTER 2 NDA-24219 Page 18Revision 2.04.2 Installation Conditions(20) The application circuit cards PN-BRTA and PN-24DTA-A cannot be mounted in slot
NDA-24219 CHAPTER 3Page 19Revision 2.0CHAPTER 3 INSTALLATION PROCEDURE1. PRECAUTIONS1.1 Grounding RequirementsThe system grounding must have a specif
CHAPTER 3 NDA-24219 Page 20Revision 2.01.2 Static Electricity GuardThe installer must wear a grounded wrist strap to protect circuit cards from stati
NDA-24219 CHAPTER 3Page 21Revision 2.0Figure 3-1 Static Electricity Guard (Continued)WEAR A WRIST STRAP AND PERFORMTHE WORK ON A GROUNDEDCONDUCTIVE
CHAPTER 3 NDA-24219 Page 22Revision 2.01.3 Removing/Inserting Circuit CardsWhen removing a circuit card from the PIM or when inserting a circuit card
NDA-24219 CHAPTER 3Page 23Revision 2.0CAUTION:Always hold the card name label area when inserting or removing a circuit card. Touching anoth-er area
CHAPTER 3 NDA-24219 Page 24Revision 2.02.PROCEDUREThis section explains the procedures for installing the PBX system. The installer should follow the
NDA-24219 CHAPTER 3Page 25Revision 2.0Figure 3-2 Procedure Flowchart (Continued)The label, shown in Figure 3-3, is attached to the NAP sheet for eac
TABLE OF CONTENTS NDA-24219 Page iiRevision 2.0TABLE OF CONTENTS (CONTINUED)Page4. CIRCUIT CARD INSTALLATION CONDITIONS. . . . . . . . . . . . . . .
CHAPTER 3 NDA-24219 Page 26Revision 2.0NAP-200-001Sheet 1/2Unpacking1. UNPACKING PROCEDURE(1) Check the received quantity of packages containing the
NDA-24219 CHAPTER 3Page 27Revision 2.0NAP-200-001Sheet 2/2UnpackingFigure 001-1 Unpacking Main EquipmentACCESSORIESPIM
CHAPTER 3 NDA-24219 Page 28Revision 2.0NAP-200-002Sheet 1/2Marking and Drilling1. CONFIRMING EQUIPMENT LAYOUTInstall the equipment in an area that pr
NDA-24219 CHAPTER 3Page 29Revision 2.0NAP-200-002Sheet 2/2Marking and Drilling3. DRILLING Install anchor bolts as shown in Figure 002-2.Figure 002-2
CHAPTER 3 NDA-24219 Page 30Revision 2.0NAP-200-003Sheet 1/12Installation of Main Equipment1. WALL-MOUNTING INSTALLATION (1) When the system is two PI
NDA-24219 CHAPTER 3Page 31Revision 2.0NAP-200-003Sheet 2/12Installation of Main Equipment(2)Using appropriate fasteners (locally provided; see Table
CHAPTER 3 NDA-24219 Page 32Revision 2.0NAP-200-003Sheet 3/12Installation of Main Equipment(3) After hanging PIM onto the wall, tighten each M4 machin
NDA-24219 CHAPTER 3Page 33Revision 2.0NAP-200-003Sheet 4/12Installation of Main Equipment(4) Connect the TOP COVER to the upper PIM with four screws,
CHAPTER 3 NDA-24219 Page 34Revision 2.0NAP-200-003Sheet 5/12Installation of Main Equipment(5) Connect the AC CORD-A-U to the AC INPUT connector on th
NDA-24219 CHAPTER 3Page 35Revision 2.0NAP-200-003Sheet 6/12Installation of Main Equipment2.19-INCH RACK-MOUNTING INSTALLATION(1)When the system is tw
NDA-24219 TABLE OF CONTENTSPage iiiRevision 2.0TABLE OF CONTENTS (CONTINUED)Page-011 Operation Test. . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 3 NDA-24219 Page 36Revision 2.0NAP-200-003Sheet 7/12Installation of Main Equipment3.DESKTOP INSTALLATION(1)When the system is two PIM configu
NDA-24219 CHAPTER 3Page 37Revision 2.0NAP-200-003Sheet 8/12Installation of Main Equipment4. AC POWER CABLING(1)The cable connections on the PZ-PW86/P
CHAPTER 3 NDA-24219 Page 38Revision 2.0NAP-200-003Sheet 9/12Installation of Main EquipmentFigure 003-7 Cable Connection on PZ-PW86/PW112 (Continued)P
NDA-24219 CHAPTER 3Page 39Revision 2.0NAP-200-003Sheet 10/12Installation of Main EquipmentFigure 003-7 Cable Connection on PZ-PW86/PW112 (Continued)P
CHAPTER 3 NDA-24219 Page 40Revision 2.0NAP-200-003Sheet 11/12Installation of Main Equipment(2)When the system is two PIM configuration, unplug the PW
NDA-24219 CHAPTER 3Page 41Revision 2.0NAP-200-003Sheet 12/12Installation of Main Equipment(3) Bring the AC CORD-A-U out of the PIM through the cable
CHAPTER 3 NDA-24219 Page 42Revision 2.0NAP-200-004Sheet 1/2PWR CA-A and BUS Cable Connection(1)When the system is two PIM configuration, connect the
NDA-24219 CHAPTER 3Page 43Revision 2.0NAP-200-004Sheet 2/2PWR CA-A and BUS Cable Connection(2) Mount the BS00 Card in the BUS slot of PIM0. Also, mou
CHAPTER 3 NDA-24219 Page 44Revision 2.0NAP-200-005Sheet 1/4Connection of Battery1. BATTERY CONNECTIONCAUTION 1:24V batteries must be used in this sys
NDA-24219 CHAPTER 3Page 45Revision 2.0NAP-200-005Sheet 2/4Connection of BatteryCAUTION 3:Battery Replacement Table and Battery WarningsThe label, whi
LIST OF FIGURES NDA-24219 Page ivRevision 2.0LIST OF FIGURESFigure Title Page1-1 Installation Reference Manuals . . . . . . . . . . . . . . . . . . .
CHAPTER 3 NDA-24219 Page 46Revision 2.0NAP-200-005Sheet 3/4Connection of Battery1.1 Internal Battery Connection(1) Mount the battery unit (24V DC, 2.
NDA-24219 CHAPTER 3Page 47Revision 2.0NAP-200-005Sheet 4/4Connection of Battery(2) Plug the battery cable connector into the BATT1 connector on the P
CHAPTER 3 NDA-24219 Page 48Revision 2.0NAP-200-006Sheet 1/2Cable Running to MDF1. MDF CABLETo facilitate the termination of the 25 pair cables (MDF c
NDA-24219 CHAPTER 3Page 49Revision 2.0NAP-200-006Sheet 2/2Cable Running to MDF2. CABLE RUNNING TO EXTERNAL MDF(1) Bring the MDF cable up to the Main
CHAPTER 3 NDA-24219 Page 50Revision 2.0NAP-200-007Sheet 1/55Termination of Cables on MDF1. CABLE CONNECTION TO MDF(1) Connect the cables to the MDF r
NDA-24219 CHAPTER 3Page 51Revision 2.0NAP-200-007Sheet 2/55Termination of Cables on MDF(2) Figure 007-2 shows the relationship between each Line Equi
CHAPTER 3 NDA-24219 Page 52Revision 2.0NAP-200-007Sheet 3/55Termination of Cables on MDF(3) Figure 007-3 shows the LTC connector pin arrangement.Figu
NDA-24219 CHAPTER 3Page 53Revision 2.0NAP-200-007Sheet 4/55Termination of Cables on MDFFigure 007-3 LTC Connector Pin Arrangement (Continued)LTC026
CHAPTER 3 NDA-24219 Page 54Revision 2.0NAP-200-007Sheet 5/55Termination of Cables on MDF2.MDF CROSS CONNECTIONSTable 007-2 shows the cross connection
NDA-24219 CHAPTER 3Page 55Revision 2.0NAP-200-007Sheet 6/55Termination of Cables on MDF* Major and minor alarm connections are used for external indi
NDA-24219 LIST OF FIGURESPage vRevision 2.0LIST OF FIGURES (CONTINUED)Figure Title Page007-21 MDF Cross Connection for TAS Indicator with Battery . .
CHAPTER 3 NDA-24219 Page 56Revision 2.0NAP-200-007Sheet 7/55Termination of Cables on MDFNote 1: When LT04 or LT06 is mounted with an 8-port card, LT0
NDA-24219 CHAPTER 3Page 57Revision 2.0NAP-200-007Sheet 8/55Termination of Cables on MDF* Major and minor alarm connections are used for external indi
CHAPTER 3 NDA-24219 Page 58Revision 2.0NAP-200-007Sheet 9/55Termination of Cables on MDF(1) C.O. Trunk(a) 4 Line C.O. Trunk (PN-4COT) (see Figure 007
NDA-24219 CHAPTER 3Page 59Revision 2.0NAP-200-007Sheet 10/55Termination of Cables on MDF(b) 8 Line C.O. Trunk (PN-8COT) (see Figure 007-5)Figure 007-
CHAPTER 3 NDA-24219 Page 60Revision 2.0NAP-200-007Sheet 11/55Termination of Cables on MDF(2) Tie Line Trunk(a) 4W E&M Trunk (PN-2ODT) (see Figure
NDA-24219 CHAPTER 3Page 61Revision 2.0NAP-200-007Sheet 12/55Termination of Cables on MDFFigure 007-6 MDF Cross Connection for 4W E&M Trunk Card
CHAPTER 3 NDA-24219 Page 62Revision 2.0NAP-200-007Sheet 13/55Termination of Cables on MDF(b) 2W E&M (PN-2ODT) (see Figure 007-7)Figure 007-7 MDF
NDA-24219 CHAPTER 3Page 63Revision 2.0NAP-200-007Sheet 14/55Termination of Cables on MDFFigure 007-7 MDF Cross Connection for 2W E&M Trunk Card
CHAPTER 3 NDA-24219 Page 64Revision 2.0NAP-200-007Sheet 15/55Termination of Cables on MDF(3) DID Trunk(a) 2 Line DID Trunk (PN-AUCA) (see Figure 007-
NDA-24219 CHAPTER 3Page 65Revision 2.0NAP-200-007Sheet 16/55Termination of Cables on MDF(b) 4 Line DID Trunk (PN-4DITB) (see Figure 007-9)Figure 007-
LIST OF TABLESNDA-24219 Page viRevision 2.0LIST OF TABLESTable Title Page2-1 Symbols in Trunking Diagram Description. . . . . . . . . . . . . . . . .
CHAPTER 3 NDA-24219 Page 66Revision 2.0NAP-200-007Sheet 17/55Termination of Cables on MDF(4) Single Line Telephone(a) Standard Line (PN-8LC) (see Fig
NDA-24219 CHAPTER 3Page 67Revision 2.0NAP-200-007Sheet 18/55Termination of Cables on MDF(b) Long Line (PN-AUCA) (see Figure 007-11)Figure 007-11 MDF
CHAPTER 3 NDA-24219 Page 68Revision 2.0NAP-200-007Sheet 19/55Termination of Cables on MDF(5) Multiline Terminal/DSS Console(a) Standard Line (PN-8DLC
NDA-24219 CHAPTER 3Page 69Revision 2.0NAP-200-007Sheet 20/55Termination of Cables on MDF(b) Long Line (PN-2DLCB/N) (see Figure 007-13)Figure 007-13
CHAPTER 3 NDA-24219 Page 70Revision 2.0NAP-200-007Sheet 21/55Termination of Cables on MDF(6) SN610- ATTCON(a) Installation of SN610 ATTCONSTEP 1:Scre
NDA-24219 CHAPTER 3Page 71Revision 2.0NAP-200-007Sheet 22/55Termination of Cables on MDFSTEP 2:To provide the console with the headset in place of th
CHAPTER 3 NDA-24219 Page 72Revision 2.0NAP-200-007Sheet 23/55Termination of Cables on MDFSTEP 3:Set the switch located inside the console according t
NDA-24219 CHAPTER 3Page 73Revision 2.0NAP-200-007Sheet 24/55Termination of Cables on MDFFigure 007-16 SN610 ATTCON Switch Setting (Continued)DSCSWIT
CHAPTER 3 NDA-24219 Page 74Revision 2.0NAP-200-007Sheet 25/55Termination of Cables on MDFSTEP 4:Plug the line cord into the modular jack located at t
NDA-24219 CHAPTER 3Page 75Revision 2.0NAP-200-007Sheet 26/55Termination of Cables on MDF(b) MDF Cross Connection (see Figure 007-18)Figure 007-18 MD
NDA-24219 REGULATORY INFORMATIONPage viiRevision 2.0REGULATORY INFORMATION1. Regulatory RequirementsThe Federal Communications Commission (FCC) has
CHAPTER 3 NDA-24219 Page 76Revision 2.0NAP-200-007Sheet 27/55Termination of Cables on MDF(7) Day/Night Mode Change by External Key (see Figure 007-19
NDA-24219 CHAPTER 3Page 77Revision 2.0NAP-200-007Sheet 28/55Termination of Cables on MDF(8) External TAS Indicator(a) Outline of the Connection (see
CHAPTER 3 NDA-24219 Page 78Revision 2.0NAP-200-007Sheet 29/55Termination of Cables on MDF(b) MDF Cross Connection• When using a TAS Indicator with a
NDA-24219 CHAPTER 3Page 79Revision 2.0NAP-200-007Sheet 30/55Termination of Cables on MDF• When using a TAS Indicator with a Battery (Ground Start) (s
CHAPTER 3 NDA-24219 Page 80Revision 2.0NAP-200-007Sheet 31/55Termination of Cables on MDF(9) Paging EquipmentFigure 007-23 and Figure 007-24 show an
NDA-24219 CHAPTER 3Page 81Revision 2.0NAP-200-007Sheet 32/55Termination of Cables on MDF(b) MDF Cross Connection (see Figure 007-24)Figure 007-24 MD
CHAPTER 3 NDA-24219 Page 82Revision 2.0NAP-200-007Sheet 33/55Termination of Cables on MDF(10) External Tone Source EquipmentThe cross connection for
NDA-24219 CHAPTER 3Page 83Revision 2.0NAP-200-007Sheet 34/55Termination of Cables on MDF(a) Outline of the Connection (see Figure 007-25)Figure 007-2
CHAPTER 3 NDA-24219 Page 84Revision 2.0NAP-200-007Sheet 35/55Termination of Cables on MDF(b) MDF Cross Connection (see Figure 007-26)Figure 007-26 M
NDA-24219 CHAPTER 3Page 85Revision 2.0NAP-200-007Sheet 36/55Termination of Cables on MDFFigure 007-26 MDF Cross Connection for External Tone Source